Isobloc - Classique H blocks

Four ranges of H

  • 4 basic H blocks: without insulation and 15 to 19 cm of concrete
  • 4 standard H blocks: with insulation and 15 cm of concrete
  • 4 H blocks (HT): with insulation and 11 cm of concrete
  • 5 structural H blocks (HS): with insulation and 16 or 18 cm of concrete
Nomenclature of H blocks

The special blocks are available for all these types of block.

Basic H blocks

The basic blocks have no insulation and 15 to 19 cm of concrete.

H 22/15

H 25/16

H 25/18

H 30/19

Type of blockH 22/15H 25/16H 25/18H 30/19
Thickness of internal wood-cement walls - cm (1)3.54.53.55.5
Exterior wood-cement wall thickness - cm (1)3.54.53.55.5
Insulation thickness - cm (2)
Concrete thickness - cm (3)15161819
Volume of concrete per square metre - l/m² (3)133142160169
Cross-section of concrete pillars - cm²300320360380
Cross-section of concrete pillars per linear metre - cm² (cm)1200128014401520
Equivalent concrete thickness - cm12.0012.8014.4015.20
Cross-section of concrete beams - cm² (cm)165176198209
Cross-section of concrete beams per metre of height - cm² (cm)660704792836
Weight of finished wall without rendering - kN/m² - 1 kN = 100 kg4.04452.004.805.27
Weight of finished wall with rendering - kN/m² - 1 kN = 100 kg4.424.855.275.69
R dry without coating - m²K/W (4)0.821.020.821.28
U dry with coating - W/m²K (5)0.9800.8000.9800.680
R without coating - m²K/W (6)0.710.910.711.14
U with coating - W/m²K (7)1.1000.8901.1000.750
Thermal offset - h (8)
Sound insulation - db (9)52535354
REI - fire resistance with loaded wall (10)180180180180

Standard H blocks

Standard H blocks have internal insulation and 15 cm of concrete.

H 30/15+7

H 33/15+10

H 38/15+14

H 43/15+19

Type of blockH 30/15+7H 33/15+10H 38/15+14H 43/15+19
Thickness of internal wood-cement walls - cm (1)4.04.04.54.5
Exterior wood-cement wall thickness - cm (1)4.04.04.54.5
Insulation thickness - cm (2)7101419
Concrete thickness - cm (3)15151515
Volume of concrete per square metre - l/m² (3)133133133133
Cross-section of concrete pillars - cm²300300300300
Cross-section of concrete pillars per linear metre - cm² (cm)1200120012001200
Equivalent concrete thickness - cm12.0012.0012.0012.00
Cross-section of concrete beams - cm² (cm)165165165165
Cross-section of concrete beams per metre of height - cm² (cm)660660660660
Weight of finished wall without rendering - kN/m² - 1 kN = 100 kg3.783.833.903.97
Weight of finished wall with rendering - kN/m² - 1 kN = 100 kg4.424.444.534.56
R dry without coating - m²K/W (4)2.743.514.615.89
U dry with coating - W/m²K (5)0.3360.2670.2060.163
R without coating - m²K/W (6)2.593.334.405.62
U with coating - W/m²K (7)0.3550.2820.2160.171
Thermal offset - h (8)-12.11-12.90-14.78-16.57
Sound insulation - db (9)54545454
REI - fire resistance with loaded wall (10)180180180180

Blocks H partitions

H blocks for partitions have internal insulation and 11 cm of concrete.

HT 30/11+11

HT 33/11+14

HT 38/11+18

HT 43/11+23

Type of blockHT 30/11+11HT 33/11+14HT 38/11+18HT 43/11+23
Thickness of internal wood-cement walls - cm (1)4.04.04.54.5
Exterior wood-cement wall thickness - cm (1)4.04.04.54.5
Insulation thickness - cm (2)11141823
Concrete thickness - cm (3)1111111/
Volume of concrete per square metre - l/m² (3)98989898
Cross-section of concrete pillars - cm²220220220220
Cross-section of concrete pillars per linear metre - cm² (cm)880880880880
Equivalent concrete thickness - cm8.808.808.808.80
Cross-section of concrete beams - cm² (cm)121121121121
Cross-section of concrete beams per metre of height - cm² (cm)484484484484
Weight of finished wall without rendering - kN/m² - 1 kN = 100 kg2.772.853.013.01
Weight of finished wall with rendering - kN/m² - 1 kN = 100 kg3.243.323.483.48
R dry without coating - m²K/W (4)3.744.585.616.88
U dry with coating - W/m²K (5)0.2520.2110.1710.140
R without coating - m²K/W (6)3.554.285.346.56
U with coating - W/m²K (7)0.2650.2220.1800.147
Thermal offset - h (8)-12.33-13.30-15.34-17.21
Sound insulation - db (9)51515151
REI - fire resistance with loaded wall (10)180180180180

Structural H blocks

Structural H blocks have internal insulation and 16 or 18 cm of concrete.

HS 33/18+7

HS 38/16+13

HS 38/18+11

HS 43/16+18

HS 43/18+16

Type of blockHS 33/18+7HS 38/16+13HS 38/18+11HS 43/16+18HS 43/18+16
Inside wall thickness - cm (1)4.04.54.54.54.5
Exterior wall thickness - cm (1)4.04.54.54.54.5
Insulation thickness - cm (2)713111816
Concrete thickness - cm (3)1816181618
Volume of concrete per square metre - l/m² (3)160142160142160
Cross-section of concrete pillars - cm²360320360320360
Pillar cross-section per metre - cm²/m14401280144012801440
Equivalent concrete thickness - cm14.4012.8014.4012.8014.40
Cross-section of concrete beams - cm² (cm)198176198176198
Beam cross-section per metre - cm²/m792704792704792
Weight of finished wall without rendering - kN/m² (kg/m²)4.424.104.524.144.56
Weight of the finished wall with rendering - kN/m² (kg/m²)4.844.524.944.564.98
R dry without coating - m²K/W (4)2.774.393.885.665.15
U dry with coating - W/m²K (5)0.3330.2160.2430.1700.186
R without coating - m²K/W (6)2.614.143.685.354.90
U with coating - W/m²K (7)0.3520.2290.2560.1790.195
Thermal offset - h (8)-12.84-14.66-14.52-16.42-16.19
Sound insulation - db (9)5455545557
REI (10)180180180180180

Explanatory note

  1. Net dry density = (500±50) Kg/m3
  2. Sintered expanded polystyrene with graphite additive. Density = 0.15 KN/m3; λ = 0.031 W/m.K
  3. Concrete density 25 KN/ m2; dry λ = 1.72 W/m.K; λ = 1.91 W/m.K with humidity in equilibrium with air at 23° C and 50% RH (ref. UNI EN 1745 and UNI EN 12524).
  4. R= Dry thermal resistance without coating and without thermal resistance limitation. Evaluation according to the theoretical method UNI EN 1745:2012. Three-dimensional method.
  5. U= Dry thermal transmittance, with 2 cm lime-sand render on the outside, 2 cm lime-sand render on the inside, with limit thermal resistance, in dry conditions. Evaluation according to UNI EN 1745:2012 theoretical method. Three-dimensional method.
  6. R= Thermal resistance, without plaster, without limitation of thermal resistance and with humidity in equilibrium with air at 23° C and 50% RH. Evaluation according to the theoretical method UNI EN1745:2012. Three-dimensional method.
  7. U= Thermal transmittance, with 2 cm lime-sand render on the outside, 2 cm lime-sand render on the inside, with limiting thermal resistance and humidity in equilibrium with the air at 23° C and 50 % relative humidity. Assessment according to UNI EN 1745:2012 theoretical method. Three-dimensional method.
  8. Ref. UNI - EN ISO 10456 standard for a 24-hour period
  9. Certified value of theoretical calculation UNI EN 12354-1:2002
  10. Ref. UNI 1365-1 standard. REI :
    - Strength: ability to maintain structural stability
    - Airtightness: ability to prevent the spread of fire and smoke through the air.
    - Insulation: the ability to thermally insulate adjacent areas and prevent the spread of heat.

A series of 5 blocks

Isobloc calculates the various blocks needed to construct the building:

  • NORMAL: standard block, shown in yellow on the plans
  • ANGLE: corner block (for external corner), in red on the drawings
  • UNIVESEL: unit for opening (door or window), in green on the plans
  • PASS: return block for corners, shown in blue on the plans
  • DUO: cutting block, in turquoise on the drawings